Product Name: | Medical Top Infusion Pump |
---|---|
Material: | PVC |
Certificate: | CE ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Veterinary Infusion Pump with Heating Function
Parameter SY-1200 Infusion pump |
|||
Conventional model |
15 d/ml infusion set 0.0ml/h~1200ml/h 20 d/ml infusion set 0.0ml/h~1200ml/h 60 d/ml infusion set 0.0ml/h~300ml/h Note:minimum resolution of setting flow rate is 0.1mL/h when rate is above 1000mL/h, the Resolution is 1mL/h.
|
||
Drip Mode |
15 d/ml infusion set 0 d/min~300 d/min 20 d/ml infusion set 0 d/min~400 d/min 60 d/ml infusion set 0 d/min~300 d/min Note:The minimum resolution dripping speed Settings 1d/min. |
||
Accuracy |
≤±2%(Note:Under the condition of the benchmark test, using high elastic silicone iv path accuracy after calibration and commissioning.) |
||
Bubble Detector |
Ultrasonic detection method:Bubble above 25ul is detected |
||
Total Infusion Volume |
0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h) |
||
Volume Limit |
0.0ml-9999ml(0.1ml/h increment,1ml/h increment if over 1000ml/h) |
||
Occlusion |
(H):800±200mmHg (106.7±26.7kPa) (C):500±100mmHg (66.7±13.3kPa) (L):300±100mmHg (40.7±13.3kPa) |
||
History Record |
These serial products can maximally store 4500 pieces of history records. The record includes the following information: Date, flow rate, alarm data, total volume delivered, occlusion pressure and syringe brand and serial number. |
||
Alarm |
Near empty alarm,Empty alarm,Door open alarm, Bubble alarm,limited value reached alarm,AC power failure,Low battery alarm,Battery empty alarm,Remind alarm,Flow regulator or inlet valve closed alarm (optional) |
||
Power |
Supply Voltage:AC100V~240V(±10%),Power Frequency: 50Hz-60Hz Built-in Battery:DC15V Ni-MH battery(It can be replaced by lithium ion battery pack necessary.) Working time of battery:In case the battery is fully charged, the continuous working time can be up to 6 hours at the speed of 25ml/h. Maximum power:30VA;Note:Before the first use of this product, the battery must be charged while being shut down for more than 12 hours. |
||
Working Environment |
Temperature:+5ºC-+40ºC Relative humidity:20%-90% Environmental pressure:860hPa-1060hPa |
||
Transport And Storage Environment |
Temperature:-20ºC~+55ºC; Atmosphere Pressure:500hPa~1060hPa. products should be stored in the relative humidity in the range of 10% ~ 93%,no corrosion gas indoor and ventilated. |
||
Electric Safety Classification |
Class I, CF type,Built-in battery,Continuous operation equipment |
||
Water Proof Level |
IPX4 |
||
Net Weight |
1.8kg(include fastener) |
||
Dimension |
175mm(W)×125mm(H)×200mm(D) |